31
NICE - MIRIAM - CRISTAL - PRETTY - KRISS - MARY - TECNA - EVO
EN
PROBLEM CAUSE SOLUTION INTERVENTION
The control display
does not switch
on
The stove is
without power
supply
Check if the plug is connected.
Burned protection
fuse in the electric
socket
Replace the protection fuses in the electric socket
(3.15A-250V).
Faulty control
display
Replace the control display.
Faulty at cable Replace the at cable.
Faulty electronic
board
Replace the mother board.
Pellets do not
reach the
combustion
chamber
Empty hopper Full the hopper.
Auger blocked by
a foreign object
(for example nails)
Clean the auger.
The auger geared
motor is out of
order
Replace the geared motor.
Check if on the
display there is an
“ACTIVE ALARM”
Have the stove checked.
The re extinguish
and the stove
stops
Empty hopper Full the hopper.
Auger blocked by
a foreign object
(for example nails)
Clean the auger.
Bad quality pellets Try other types of pellets.
Pellet drop value
too low “phase 1”
Adjust the pellet loading.
Check if on the
display there is an
“ACTIVE ALARM”
Have the stove checked.
Stove running and
display showing
“BURN POT
CLEANING”
Automatica
burning pot
cleaning
The stove is at minimum, fume fan at maximum. NO
PROBLEM!