p. 19 - Manual FA01332-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
CZ input
Associate a function with the CZ input.
F4 CZ input OFF (Default)
C1 = Reopening while closing (Photocells)
C4 = Obstacle wait (Photocells)
C5 = Immediate closing at the opening travel end
C7 = Reopening while closing (sensitive safety-edges)
C9 = immediate closing at the travel end during opening with obstacle waiting, during
closing
C10 = Immediate closing during opening with obstacle waiting during closing
r7 = reopening while closing (sensitive safety-edges with 8K2 resistor)
Safety devices test
It activates the check of the correct operation of the photocells connected to the inputs, after each opening and closing command.
F5 Safety devices test OFF (Default)
1 = CX
2 = CY
3 = CZ
4 = CX+CY
5 = CX+CZ
6 = CY+CZ
7 = CX+CY+CZ
Maintained action
With the function active, the operator movement (opening or closing) is interrupted when the control device is released.
Activation of the function excludes all other control devices.
F6 Maintained action OFF (Default)
ON
Obst. with motor stopped
With the function active, the boom remains stopped if the safety devices detect an obstacle. The function activates with: closed rod, open rod or after a total stop.
F9 Obst. with motor stopped OFF (Default)
ON
Open warning light
It warns of the state of the barrier.
F10 Open warning light 0 = Warning light on (Default) - The light stays on when the boom is moving or open.
1 = Warning light flashing - The warning light flashes every half second when the
boom is opening and stays on when the boom is open. The light flashes every second
when the boom is closing and is off when the boom is closed.
Sensor type
It sets the type of control device.
F14 Sensor type 0 = Transponder
1 = Keypad (Default)
Electric lock
It allows to choose the electric lock activation mode during the boom maneuvering phases.
F17 Electric lock OFF = Electric lock deactivated (Default).
1 = The electric lock is deactivated during the boom opening and remains deactivated
until the boom is closed again.
3 = The electric lock is deactivated during the boom opening or closing operations, but
it is active when the barrier is open or closed.