Add User
It is used to register a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or other control device. The boards that manage the control devices (AF - R700 - R800) must be
plugged into the connectors.
From the docs.came.com portal, download the LIST OF REGISTERED USERS form, type L20180423.
U1 Add User 1 = Step-step
3 = Open
4 = Partial opening
When the barrier is in [combined] mode, the [Partial Opening] command opens the
Master barrier.
When the barrier is in the [Alternate] mode, the [Partial Opening] command opens the
Slave barrier.
1 - Choose the function to be assigned to the user.
2 - Press ENTER to confirm.
The user code must be entered.
3 - Send the code from the control device.
Repeat the procedure for adding other users.
Remove user
It removes one of the registered users.
U2 Remove user OFF (Default)
ON
No.: 1 > 250
Use the arrows to choose the number associated with the user to be removed.
Alternatively, the control device associated with the user to be removed can be
activated.
Press ENTER to confirm.
Remove all
It removes all registered users.
U3 Remove all OFF (Default)
ON
Radio-frequency decoding
For choosing the type of radio coding of the transmitters enabled to control the operator.
Choosing the type of radio coding of the transmitters [Rolling code] or [TW key block], the transmitters with different type of radio coding previously
stored, will be deleted.
U4 Radio-frequency decoding 1 = All (Default)
2 = Rolling code
5 = TW Key Block
Boom length
Sets the boom length.
A1 Boom length 1 = up to 2.5 m (Default)
2 = from 2.5 to 3.8 m
Motor test
Verification of the correct opening direction of the boom.
If the keys do not execute the commands correctly, invert the boom opening direction.
A2 Motor test The button < makes the motor turn in a counter clockwise direction.
ON = to activate the TEST.
Travel calibration
It starts the travel self-learning.
A3 Travel calibration ON = To start calibration