Keyword Information and Location
RS232Power
Controls whether the RS-232 port will remain active even when
communications are not taking place. Note that if RS232Handshaking is
enabled (handshaking buffer size is non-zero), that this setting must be
set to Yes.
l Boolean data type
Where to find:
l Settings Editor tab in Device Configuration Utility: Advanced |
RS232 Always On
RS232Timeout
RS-232 hardware handshaking timeout. Specifies the time (tens of ms)
that the CR1000X will wait between packets if CTS is not asserted.
l Numeric data type
Where to find:
l Settings Editor tab in Device Configuration Utility: Advanced |
RS232 Hardware Handshaking Timeout
Security(1)
Security(2)
Security(3)
An array of three security codes. A value of zero for a given level will
grant access to that level's privileges for any given security code. For
more information, see Datalogger security (p. 100).
l Numeric data type
Where to find:
l Settings Editor tab in Device Configuration Utility: Datalogger |
Security Level 1, 2, or 3
ServicesEnabled
Discontinued; replaced by/aliased to HTTPEnabled, PingEnabled,
TelnetEnabled.
TCPClientConnections
Discontinued; replaced by / aliased to PakBusTCPClients.
9. Tips and troubleshooting 157