DFC Weighing Procedure (Load Mode):
1. Verify the scale is in Load mode (the Unload annunciator will be
turned off). You can toggle back and forth between Load and
Unload mode by pressing the LOAD/UNLOAD key.
2. With the scale empty, verify the scale is showing 0 units Gross.
If not in Gross mode, press the 0 key then the TARE key to
clear the stored tare weight and the indicator will display Gross
weight.
3. If the scale is showing a weight different than 0, press the
ZERO/CLEAR key to zero the scale.
4. If you wish to use a tare weight, place a tare weight on the scale
then press the TARE key; Or if you know the tare weight, you
can manually enter it by keying in the value followed by the
TARE key.
5. The scale is now ready to be Loaded using the DFC. Press the
ID/START key to start the cycle.
6. If at any time, you wish to pause the fill cycle, press the HOLD
key. The indicator will display PAUSED. To restart/continue the
filling operation, press the HOLD key again to “unpause.” Or to
abort the fill, press the * key.
7. Chattering will begin once the chatter weight is reached (fill
weight – trim weight). When chattering, the DFC output will
pulse on and off. The settings for these pulse durations are
described in the Recommended Settings section above.
8. The fill cycle will end once the preset fill weight is reached. (**)
If DFCEND=YES was selected, the indicator will display “ DONE
until a key is pressed.
9. Remove the material from the scale. Repeat these steps for
subsequent fill cycles. If you wish to continue using the stored
tare weight, skip steps 1 to 4.
10. If you have a value set for PURGE above, the indicator will be
counting the number of fill cycles completed and once the purge
count (PURGE value) is reached, the purge weight (P-WGT) will
be added to the trim weight and flash PURGE FEEDER on the
display. At this time, you would

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 212 Series and is the answer not in the manual?

Cardinal 212 Series Specifications

General IconGeneral
BrandCardinal
Model212 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals