212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
2.4 INDICATOR OPERATIONAL SETUP REVIEW
This section describes another Setup Review that will only prompt for
operational parameters (e.g., DFC parameters, digital filtering).
Accessing and Navigating the Operational Setup Review
1. With the indicator ON, press the F key followed by the PRESET key.
2. At each prompt, press the ENTER key to display the current value
associated with that prompt.
3. To modify any current value, enter the desired value and then press
the ENTER key.
4. Otherwise, press the ENTER key to keep the current value and
advance to the next prompt.
5. To step past a group of parameters, press the F key.
6. To step backwards to a previous prompt, press the key.
7. To exit this menu, press the ENTER key after the last prompt or press
the key at the first prompt.
Operational Setup Review Parameters
Digital Output Control Enable/Disable and Settings
The following prompts are only displayed when D-Out= 4 or 14
Number of Digital Fill Cycles before purging feeder
Purge Weight – The amount of material contained in
feeder before purge.
The next prompt is only displayed when D-Out= 1 or 11
The next prompt is only displayed when DOUT= 4 or 14 and FMODE= 0
Single or Dual speed DFC operation