212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 117
Plot-Tracker DFC Mode (Plot Fill)
This DFC mode expands on the Box-Tracker DFC mode. In this mode, the 10 of
the 100 memory ID locations are used to keep track of a material’s remaining Net
weight (Box Tracker). The remaining 90 memory ID locations are used to keep
track of how much material is delivered to a specific plot (Plot Tracker). This
mode also will default to a 2-speed, chatter gate operation (non-selectable) with
no auto-trim.
Recommended Settings:
D OUT= 4 (Required for DFC)
OR
D OUT= 14 (Required for DFC with inverted outputs)
FMODE= 3 (Required for Plot Fill)
FIL-AA= YES for each completed fill weight to be added to an accumulator
PURGE= N Where N the number of fill cycles you require before a manual feeder
purge will take place. Set to 0 to disable
P-WGT= This is the weight of material contained within the feeder you will be
purging.
CHATR= This is the amount of time (in seconds) the output will be active when
chattering.
CHTOFF This is the amount of time (in seconds) the output will be inactive when
chattering.
TRMWT= This is the trim weight. Target weight – trim weight = weight at which
chattering will begin.
A-PRNT= YES If using a printer, this will automatically print at the end of a fill cycle
DFCEND YES If you want the indicator to display DONE upon completion of a fill
cycle.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 212 Series and is the answer not in the manual?

Cardinal 212 Series Specifications

General IconGeneral
BrandCardinal
Model212 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals