212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
CAL2= – Second Calibration Weight
1. The display will show CAL2=0. This is the second of two
calibration weights. This weight could be ZERO (NO LOAD)
or the TEST WEIGHTS (TEST LOAD).
2. Press the ENTER key to view the current setting.
3. If the second calibration weight is to be ZERO (NO LOAD),
press the ENTER key.
4. If the second calibration weight is to be the TEST WEIGHTS
(TEST LOAD), use the numeric keys to input the value of the
test weights.
5. Place the weights on the scale platform, then press the
ENTER key.
6. Starting at the left and proceeding right, a series of dashes
will appear on the display.
7. Next, starting at the left and proceeding right, the dashes will
disappear, after which the display will show: SIO?.