7.8
DISPLAY POSSIBLE CAUSE EFFECT INTERVENTION
FRESH BREW GROUP ERROR - 1
ERROR
11:25 | 19 Febbraio 2015
131°
Error page
Mechanical fault
during the re-start pro-
cedure.
Dispensing not
allowed
● Open the upper front door.
● Check the Fresh Brew unit.
● If necessary, replace.
FRESH BREW GROUP ERROR - 2
ERROR
11:25 | 19 Febbraio 2015
131°
Error page
0 position not detect-
ed by the sensor.
Dispensing not
allowed
● Open the upper front door.
● Check the Fresh Brew unit.
● If necessary, replace.
FRESH BREW GROUP ERROR - 3
ERROR
11:25 | 19 Febbraio 2015
131°
Error page
The opening waiting
time of the Fresh Brew
unit has elapsed.
Dispensing not
allowed
● Open the upper front door.
● Check the Fresh Brew unit.
● If necessary, replace.
FRESH BREW GROUP ERROR - 4
ERROR
11:25 | 19 Febbraio 2015
131°
Error page
The waiting time of
half opening of the
Fresh Brew unit has
elapsed.
Dispensing not
allowed
● Open the upper front door.
● Check the Fresh Brew unit.
● If necessary, replace.
7.4 FRESH BREW UNIT ERRORS