3.1 FIRST INSTALLATION AND START-UP
3.1.1 Positioning of the machine
Position the machine:
• Indoor with temperature above 5 °C.
• At a minimum distance of 150 mm from
walls or other objects, to facilitate ven-
tilation.
• Horizontally,onaat,stablesurface,at
a minimum height above 700 mm and
below 960 mm.
WARNING
Position the machine on a horizontal sur-
face.
WARNING
Do not obstruct the openings or slots for
ventilation or heat dissipation and do not
insert water or any kind of liquid.
WARNING
In case of prolonged storage at a tempera-
ture below 2 °C, empty the machine hy-
draulic system. Do not switch the machine
on before having reconditioned it for at
least 1 hour at a suitable room tempera-
ture. If it is installed in areas with room
temperature above 30 °C, malfunctioning
may occur.
30°C > > 5°C
= 30÷70% non-condensing
600 mm
150 mm
<960 mm
>700 mm