4.2. Check Equipment
Inspect equipment. File a claim with shipping company prior to
installation if shipment is damaged or incomplete.
4.3. Location
All wiring must comply with national, state, and local codes.
4.3.1. Wall Control
The Infinity System Control is the command center for the Infinity
System. It should be located where it is easily accessible and visible to
the adult homeowner or end user. For accurate temperature measurement,
the following guidelines should be followed:
The Infinity System Control, Remote Room Sensors and Smart Sensors
SHOULD be mounted:
Approximately 5-ft (1.5 m) from the floor.
Close to or in a frequently used room, preferably on an inside
partitioning wall.
On a section of wall without pipes or ductwork.
The Infinity System Control and Sensors SHOULD NOT be mounted:
Close to a window, on an outside wall, or next to a door leading to the
outside.
Exposed to direct light or heat from a lamp, sun, fireplace, or other
temperature-radiating objects which could cause a false reading.
Close to or in direct airflow from supply registers.
WARNING
!
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or death.
Disconnect power before routing control wiring.