39
A14225A_2
6.3.3.1.   Furnace Airflow
Selects  the airflow of the  furnace when  heating.  EFFICIENCY is  the
airflow  used  to  meet  specified  ratings,  COMFORT  is  a  decreased
airflow used to increase the output air temperature and provide increased
comfort.
For the Low heat rise option, set to ON if the system contains a bypass
humidifier. The ON setting will increase the furnace low heat airflow.
After the selections are made, touch SAVE.
• Furnace Air Flow: Comfort or Efficiency. Default = Comfort
• Low Heat Rise: On or Off. Default = Off
6.3.3.2.   AC/HP Airflow
NOTE: For Geothermal Heat Pumps, this option will be shown as ’Geo
HP’ airflow. This option elects the airflow of the furnace when cooling,
heat pump heating, and  dehumidification when used  with a geothermal
heat pump.
The QUIET airflow means the minimum cooling airflow that the system
can safely run (typically 300 CFM/ton). Use this setting if duct noise is a
severe problem. 
NOTE: Duct sweating in high humidity environments could become an
issue at low airflows. 
The COMFORT airflow means airflow is varied depending on humidity
and  temperature  demand  settings.  This  selection  enables  the  full
dehumidify  and  comfort  capabilities  of  the  system.  The  EFF325  (or