53
equipment does not stage down due to airflow, but the system may stage
down due to high static pressure.
CFM  associated  for  each  limit  is  shown  on  the  screen.  Compare  this
value  with  the  equipment’s  low  stage  CFM  value  to  ensure  that
equipment  will  run  for  each  zone.  Assessed  airflow  is  determined  as
described in DUCT ASSESSMENT.
After the selections are made, touch SAVE.
• Touch the zone name that you wish to change
• Select  the  zone  to  adjust  airflow:  Low,  Med-Low,  Medium,
Med-High, High, or No Limit. Default = High
6.3.8.4.   Duct Assessment Time
NOTE:  The  daily  duct  assessment  will  occur  even  if  static  pressure
monitoring  is  disabled.  This  is  done  to  ensure  that  the  system  will
continue to provide proper airflow for all installed equipment, since duct
system  changes  may  occur  at  any  time,  such  as  opened  or  closed
registers.
This  option  allows  the  installer  to  select  the  time  in  which  the  duct
assessment will be performed. After the selection is made, touch SAVE.
• Duct  Assessment  Time:  Selectable  between  12  AM  and  11PM.
Default = 1 PM
6.3.9.   Accessories
First touch SETUP, then touch ACCESSORIES to set up the parameters
for the accessories installed with the system.
6.3.9.1.   Filter
NOTE:  The  daily  duct  assessment  will  occur  even  if  static  pressure
monitoring  is  disabled.  This  is  done  to  ensure  that  the  system  will
continue to provide proper airflow for all installed equipment, since duct