SHANDONG CARTER HEAVY INDUSTRY MACHINERY CO., LTD.
13
25. Prevent fire
(a) Check the oil spills
Fuel oil, hydraulic oil and grease leaks may cause fire
disaster.
Check whether the holder is missing or loose, the hose is
twisted Knot, or hose, piping friction between oil cooling is
damaged, and oil cooler flange bolts are Relaxation, in order to
avoid oil spills.
The tightening, repair or replace any missing, relaxation or
damage the holder, piping, hoses, oil cooler and its law blue
bolt.
Do not bend or strike high pressure lines.
Do not install bent or damaged pipe, tube or hose.
(b) Check the short circuit
A short circuit will cause a fire.
Clean and tighten all circuit connections.
In each shift before or after 8-10 hours of operation, check the cable and wire is loose, kink, hard or cracked.
Before each shift, or 8-10 hours after the operation, then check stud end cap is lost or damaged.
Do not operate the machine if cables or wires relaxed and kinked.
(c) Clear combustibles
Spilled fuel and hydraulic oil, garbage, grease, broken debris and other combustible materials may cause a fire.
Check and clean machine every day, promptly remove spilled or accumulation of combustible material, to prevent
fire.
(d) Check the key switch
Fire if not stop the machine, it will increase the fire situation is not conducive to the fire. Daily before operating the
machine must to check the function of the key switch, to start the engine, in order to idle speed no-load operation,
the key switch to OFF position, and confirm whether the engine is came to a halt or not.
(e) To prevent lighting equipment cause an explosion
When checking the fuel, oil, battery electrolyte, windows
Washing-up liquid coolant, to use explosion prooflighting equipment.
If not use this kind of lighting equipment, the explosion caused
serious injury.
When the power of the machine used for lighting, to comply with
the prescribed instructions.
(f) Check the heat shield
Shrouds damage or loss may cause a fire.
If any abnormalities are found, make sure before operating the
machines Repair or coupled with new heat shield.
26. Measures in the event of fire