EasyManua.ls Logo

CAS CI-100A - 4.2 CONFIG Submenu (Continued)

CAS CI-100A
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA Corporation
www.cas-usa.com 10
PRIM.Ut
KG
KG
Select the primary unit from kg or lb.
The second unit is the lb if kg selected as
primary unit or kg if lb selected as primary
unit.
LB
SECND.N
100-
125,000
3000
the division number under second unit,the
max is 1.25*(PRIM.N), and
if(REGULAR)none, the max is 10,000
10N.DSP
NO
NO
Display weight at 10 times division number
under primary unit, if (REGULAR)=none, no
this item
YES
MOTION 1-255 4
Check motion window: 1-255=±0.25d
*(1-255), if (REGULAR)
none, the max is
12
OVER.LD 0-100 0
over load display limitation: 0=FS+9d,
1-100=101%FS -200%FS, if
(REGULAR)
none, the max is 10
AD.FROM
ADC
ADC
Weight Data comes from: ADC=local A/D
chip on PCB; COM3=COM3 interface;
COM3
AD.H.SPD
NO
NO
Speed of A/D convert: NO=10Hz;
YES=80Hz; if AD.FROM=COM3,this item
will not be shown
YES
UNITS
KG
YES
YES
Units that can be used by UNIT key select:
YES=enable this unit to be used;
NO=disable this unit to be used;
Refer to sectioon5.12 for some limitation; In
trade application, lb:oz should not be
allowed.
NO
LB
YES
YES
NO
OZ
YES
NO
NO
LBOZ
YES
NO
NO
G
YES
NO
NO
ZRO.PNT
IZSM 0-100 10
Initial zero(power on zero) point range:
0=no limitation, 1-100= (calibration zero
point) ±1%FS - (calibration zero point)
±100%FS, If (REGULAR)none, the max is
10
IN.IZSM
WEIGHT
WEIGHT
Choose which weight as current initial zero
point when current weight is in
IZSM range:
WEIGHT= current weight ; CAL.ZRO=
calibration zero; LAST.Z.T=switch-off zero
and tare
If (REGULAR)
none, the value is fixed on
WEIGHT
CAL.ZRO
LAST.Z.T
OV.IZSM
DSP.OVR
DSP.OVR
Choose which weight as current initial zero
point when current weight is over
IZSM
range: DSP.OVR=display initial zero is
over; WEIGHT= current weight;
CAL.ZRO= calibration zero;
LAST.Z.T=switch-off zero and tare
If (REGULAR)
none, the value is fixed on
DSP.OVR
WEIGHT
CAL.ZRO
LAST.Z.T

Related product manuals