EasyManua.ls Logo

CAS CI-100A - 4.3 USER Submenu (Continued)

CAS CI-100A
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA Corporation
www.cas-usa.com 14
PRINT
received; (5)PRT.CMD= output after PRINT key
pressed or request command received;
(6)STABLE=output after scale is stable;
Note: use PRINT or CMD to output data, the
scale must be stable.
CMD
PRT.CMD
STABLE
LAYOUT
MULTPL
MULTPL
com2 output content and format set:
(1)MULTPL= the following selected item in
OUT2 will be output use defined format;
(2)SINGLE= only displayed content and current
status will be output, it’s compatible with
NCI-SCP01; (3) EH-SCP= Command
–response mode, similar to Toledo PS60
protocol; 4SCP-12 = only displayed content
and current status will be output, it’s compatible
with NCI-SCP12NCI3835;
SINGLE
EH-SCP
SCP-12
OUT2 SCAL.ID
YES
NO
Yes/No=enable/disable output scale's ID
number, Prompt is “SCALE ID”
NO
GROSS
YES
NO
Yes/No=enable/disable output gross weight.
Prompt is “GROSS”
NO
TARE
YES
NO
Yes/No=enable/disable output tare weight.
Prompt is “TARE”
NO
NET
YES
YES
Yes/No=enable/disable output net weight.
Prompt is “NET”
NO
PERCNT
YES
NO
Yes/No=enable/disable output weight
percentage. Prompt is “PERCENTAGE”
NO
UPCTWT
YES
NO
Yes/No=enable/disable output weight of 1%
percentage. Prompt is “1% REF WT”
NO
COUNT
YES
NO
Yes/No=enable/disable output counts. Prompt is
“QUANTITY”
NO
PCWT
YES
NO
Yes/No=enable/disable output piece weight.
Prompt is “PIECE WT”
NO
BMI
YES
NO
Yes/No=enable/disable output height and BMI.
Prompt is “HEIGHT” and “BMI”
NO
ACCUMU
YES
NO
Yes/No=enable/disable output accumulation
times and total. Prompt is “ACC. N” and
“TOTAL”
NO
DATE
YES
NO
Yes/No=enable/disable output date. Prompt is
“DATE”
NO
TIME
YES
NO
Yes/No=enable/disable output time. Prompt is
“TIME”
NO
AD.CODE
YES
NO
Yes/No=enable/disable output ADC's code.
Prompt is “A/D CODE”
NO
BAT.VOL
YES
NO
Yes/No=enable/disable output voltage of
battery. Prompt is “VOLTAGE”
NO
STATUS
YES
NO
Yes/No=enable/disable output scale's status.
Prompt is “STATUS”
NO