EasyManua.ls Logo

CAS CI-100A - 4.3 USER Submenu (Continued)

CAS CI-100A
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA Corporation
www.cas-usa.com 15
B.LINE
NONE
LINE1
How many blank lines after strings output:
NONE=no blank line, LINE1/2/3/4=there're 1,
2,3 or 4 blank lines after strings, used for
paper feed forward 1/2/3/4 lines.
LINE1
LINE2
LINE3
LINE4
COM3* BAUD.RT
1200
9600 selection of com3's baud rate
2400
4800
9600
19200
BYT.FMT
8N1
8N1
selection of com1's byte format:
(1)8N1=8 data bits, No parity check bit, 1 stop
bit; (2)7O1=7 data bits, 1 Odd parity check
bit, 1 stop bit; (3)7E1=7 data bits, 1 Even
parity check bit, 1 stop bit; (4)7O2=7 data
bits, 1 Odd parity check bit, 2 stop bit;
(5)7E2=7 data bits, 1 Even parity check bit, 2
stop bit;
7O1
7E1
7O2
7E2
OUT.MOD
NONE
PRTCMD
Select com3 output mode: (1) NONE = No
communication ; (2)CONT=continuously output;
(3)PRINT=output after PRINT key pressed;
(4)CMD=output after a request command is
received; (5)PRT.CMD= output after PRINT key
pressed or request command received;
(6)STABLE=output after scale is stable;
Note: use PRINT or CMD to output data, the
scale must be stable.
CONT
PRINT
CMD
PRTCMD
STABLE
LAYOUT
MULTPL
MULTPL
Com3 output content and format set:
(1)MULTPL= the following selected item in
OUT3 will be output use defined format;
(2)SINGLE= only displayed content and current
status will be output, it’s compatible with
NCI-SCP01; (3) EH-SCP= Command
–response mode, similar to Toledo PS60
protocol; 4SCP-12 = only displayed content
and current status will be output, it’s compatible
with NCI-SCP12NCI3835;
SINGLE
EH-SCP
SCP-12
OUT3* SCAL.ID
YES
NO
Yes/No=enable/disable output scale's ID
number, Prompt is “SCALE ID”
NO
GROSS
YES
NO
Yes/No=enable/disable output gross weight.
Prompt is “GROSS”
NO
TARE YES
NO
Yes/No=enable/disable output tare weight.
Prompt is “TARE”
NO
NET
YES
YES
Yes/No=enable/disable output net weight.
Prompt is “NET”
NO
PERCNT YES
NO
Yes/No=enable/disable output weight
percentage. Prompt is “PERCENTAGE”
NO