CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA Corporation
www.cas-usa.com 40
23.7 Communication Details when USER-COM1/2-LAYOUT is set to MULTIPLE:
23.7.1 Output string frame:
<LF><Prompt><p>W
1
W
2
W
3
W
4
W
5
<Dp>W
6
U
1
U
2
U
3
U
4
U
5
<CR>
…… ---- Line number and content are determined by setting of USER-OUT1/2-xxxx
<LF><Prompt>H
1
H
2
H
3
H
4
<CR> ---- USER-OUT1/2-STATUS is set to YES
……
<LF>
(1)The decimal point position is determined by CONFIG-PRIM.D
(2)The unit position and bytes is determined by which current unit is used.
(3)The details of <Prompt> refer to the content in 4.3USER Submenu.
(4)In hold mode, if ADC conversion speed is set high speed (80Hz), and USER-COM1/2-LAYOUT is
set to MULTIPLE, and many contents are selected to output, the output contents from COM1 or COM2 may
not catch up with the data processed in indicator, So, if you want to watch “real time” data, you need to select
fewer output contents and set higher baud rate for C<CR> --- USER-OUT1/2-LINE is set to LINE1/2/3/4
…… ---The number of blank lines is determined by USER-OUT1/2-LINE setting
<ETX> --- Last byte of string frame
23.7.2 Examples of some layout when USER-OUT1/2-xxxx is set to YES (USER-COM2-EN.ADDR=No):
23.7.2.1 In weighing mode:
SCALE ID: 123456
GROSS: 123lb 4.56oz
TARE: 11lb 2.22oz
NET: 112lb 2.34oz
ACC. N: 8
TOTAL: 789lb 15.2oz
DATE: 2011-06-12
TIME: 12:34:56
A/D CODE: 1234567
VOLTAGE: 6.7V
STATUS: bpq2
23.7.2.2 In counting mode:
SCALE ID: 123456
GROSS: 1234.55kg
TARE: 12.15kg
NET: 1222.40kg
QUANTITY: 24448pcs
PIECE WT: 0.05kg
ACC. N: 10
TOTAL: 23456pcs