31
H. Unit weight recomputing
● Keep pressing ENTER key in USER PROGRAMMING MODE until the display
appears as below.
●
There are 2 options, and Pressing MOVE key is possible to rotate among the options.
(Default setting: 1)
0 – Disable recomputing function
1– Enable recomputing function
● If you want to exit, press C key to confirm and go back to normal weighing mode.
However, if you want to keep going to set other menus, press ENTER key to confirm and
move on next.
※
The unit weight will be averaged again if you add the remaining quantity, gradually,
by several lots.
This will help eliminate errors caused by the possible weight
variation among each object
and lead to more accurate results.
When adding objects to the platform (The weight value should not be less than
10 display divisions.), be sure that the quantity is LESS THAN those already on
the platform. The alarm will sound a beep when the unit weight is averaged again.
※
Recomputing function is effective only after sampling operation is done.
※
Please turn off the scale after setting.