Serial I/F Mode setting (Under F43-00 setting, only) Port 2(Option)
F42
0
Steam Mode : Continuous Data transfer
1
Finish Mode : Single time data transfer, after Finish relay ON
- When Finish Relay output, Data will be output.
2
Print Mode : Single time data transfer, when print key input
Serial I/F Transference method setting Port 2(Option)
F43
0
Simplex Mode
1
Duplex Mode / Command Mode
2
LCD Mode
Transferred Data Format Port 2(Option)
F45
0
Format 1.
1
Format 2. (Format 1 + time)
2
Format 3.
Data Transference count setting Port 2(Option)
F47
0
About 40times/sec
1
About 30times/sec
2
About 20times/sec
3
About 15times/sec
4
About 10times/sec
5
About 5times/sec
6
About 3times/sec
Serial Printer Setting
Weight Unit selection (Printer)
F50
0
kg
1
g
2
t
AUTO Print Selection
F51
0
When Weight is steady over than Empty Range, Automatically print.
- Check Empty Range
1
Over than Empty Range, Steady Lamp is “ON”, Automatically Print.