6-MAINTENANCE
Hydraulicoillevel
WARNING
Burnhazard!
Beforeperforminganyserviceonthehydraulicsystem,youmustallowittocool.Hydraulicuid
temperatureshouldnotexceed40°C(104°F).
Failuretocomplycouldresultindeathorseriousinjury.
W0241A
Checkthehydraulicoillevelevery10horeveryday
Fluid:PREMIUMHYDRAULICOILHV46MULTI-GRADEANTIWEAR
1.Parkthemachineonaatandlevelplace,andarrange
theattachmentasshowninthegure.Stoptheengine,
andremovethestarterkey.
SMIL18CEX0485AA1
2.Opentheright-handdoor,andchecktheindicatorof
thehydraulicoillevel.Theoillevelshouldbeinthe
middleofthebandindicatedbythetwolines.
SMIL18CEX0486AA2
3.Ifthehydraulicoillevelisnotinrangeproceedasfol-
lows:
Releaseallpressureinthehydraulictank.Referto
page6-8.
Cleanthetopsurfaceofthehydraulictank.
Removethecoverofthesuctionlter,andsupply
hydraulicuidtothetank.
Ifnecessary,replacethesealofthecoverplate,and
attachthecoverofthesuctionlter.
NOTICE:makesurethatnocontaminant(water,sandetc.)
entersthereservoirduringlling.
SMIL18CEX0487AA3
6-18