6-MAINTENANCE
Every2000hours
Hydraulicoilsuctionlter
WARNING
Burnhazard!
Beforeperforminganyserviceonthehydraulicsystem,youmustallowittocool.Hydraulicuid
temperatureshouldnotexceed40°C(104°F).
Failuretocomplycouldresultindeathorseriousinjury.
W0241A
WARNING
Pressurizedsystem!
Neverattempttodrainuidsorremovelterswhentheengineisrunning.Turnofftheengineand
relieveallpressurefrompressurizedsystemsbeforeservicingthemachine.
Failuretocomplycouldresultindeathorseriousinjury.
W0905A
Cleanthehydraulicoilsuctionlterevery2000h
NOTICE:Ifanyattachmentotherthanabucketisused,reducetheintervalofthehydraulicoilsuctionltercleaning.
RefertoChapter9.
NOTICE:Ifyoundanymetalparticlesontheoldlters,consulttheCASECONSTRUCTIONdealer.
NOTICE:Replacethehydraulicoilsuctionlterevery5000hofoperationorwhenhydraulicuidisreplaced.
1.Releaseallthepressureinthehydraulictank.Referto
page6-8.
2.Cleanthetopofthehydraulictank,andcleanthecover
ofthesuctionlter.
3.Removethecover(1),andtheO-ring(2)locatedontop
oftherodassemblyofthesuctionlter.
4.Removetheoilsuctionlter(3),andcleanitwitha
solvent.
Letitdrycompletely,andcheckfordamage.Ifany
damageisfoundonitssurface,replaceitwithanew
component.
5.Attachthesuctionlter(3)andtherodassembly.
6.ReplacetheO-ring(2).
7.Attachthecover(1).
8.Checkthehydraulicuidlevel,andsupplyitifneces-
sary.
SMIL17CEX0165BA1
6-59