6-MAINTENANCE
Travelreductionunitsoil
Replacethetravelreductionunitsoilevery1000h(After250hofoperationinrun-inperiod)
Lubricant:HYPOIDGEAROILEXTREMEPRESSURE80W-90
Quantity:2.1L(0.6USgal)(pertravelreductiongear)
1.Parkthemachineonat,horizontalground.
2.Movethemachinesothatthedrainplug(1)comes
downtothelowestposition.
3.Stoptheengine,andremovethestarterkey.
4.Placeacontainerwithanappropriatecapacityunder
thetravelreductiongear.
5.Removethelevelplug(2).
6.Removethedrainplug(1).
NOTE:Checktheconditionofthedrainedoil.Ifthereare
piecesofmetalorforeignobjectsintheoil,consultthe
CASECONSTRUCTIONdealer.
7.ReplacetheO-ringsealofthedrainplug(1).Insertthe
drainplug(1)withsealtapewrappedaroundit.Add
oilthroughport(2)untiltheoilcomesuptothebottom
edgeoftheport.
8.ReplacetheO-ringsealofthelevelplug(2).Insertthe
levelplug(2)withsealtapewrappedaroundit.
9.Repeatsteps2to8fortheothertravelreductiongear.
10.Runthemachineslowlytocheckthatthereareno
leaks.
SMIL15CEX9565AA1
6-57