EasyManua.ls Logo

Case CX130C - When Necessary; Fuel Feed Pump

Case CX130C
282 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-MAINTENANCE
Whennecessary
Fuelfeedpump
WARNING
Flyingdebris!
Compressedaircanpropeldirt,rust,etc.intotheair.Weareyeandfaceprotectionwhenusingcom-
pressedair.
Failuretocomplycouldresultindeathorseriousinjury.
W0307A
Cleantheelectromagneticfuelfeedpumpperiodically.
Thefuelfeedpumpislocatedbehindtheleft-handfuel
pre-lter.
Tocleanthefeedpumpproceedasfollows:
1.Placeacontainerwithanappropriatecapacityunder
thefeedpump.
2.Closethefuelcutvalve.
3.
Disconnecttheelectriccablefromthefeedpump.
Carefullydisconnectthefuellinesfromthefeedpump.
4.Removethemountingscrewsandtakeoutthefeed
pumpforcleaning.
5.Openthepumpbody,andpulloutthelter(2)andthe
seals(1)and(3).
6.Cleanthelterbycompressedair.Checkthelter,and
replaceitifnecessary.
7.Replacetheseals(1)and(3).
8.Cleanthebody(4)andthecover(5)carefully.
Makesurethatthefeedpumpisfreefromtheaccumu-
lationofdirt.
9.Attachtheseals(1)and(3)tothelter(2)inthecorrect
order,thencarefullyinsertthesealsandthelterinto
thepumpbody.Closethecover(5)ontothepumpbody
(4).
10.Installthefeedpumpwiththemountingscrews.
11.Connectthefuellinestothefeedpump.Connectthe
electriccabletothefeedpump.
12.Bleedthefuelsystem.Refertopage6-9.
SMIL17CEX0174AA1
SMIL17CEX0184AA2
EQFU5N-0033
6-72