6-MAINTENANCE
Every5000hours
Hydraulicoilandlters
WARNING
Burnhazard!
Beforeperforminganyserviceonthehydraulicsystem,youmustallowittocool.Hydraulicuid
temperatureshouldnotexceed40°C(104°F).
Failuretocomplycouldresultindeathorseriousinjury.
W0241A
WARNING
Pressurizedsystem!
Neverattempttodrainuidsorremovelterswhentheengineisrunning.Turnofftheengineand
relieveallpressurefrompressurizedsystemsbeforeservicingthemachine.
Failuretocomplycouldresultindeathorseriousinjury.
W0905A
CAUTION
Escapinguid!
Hydraulicuidordieselfuelleakingunderpressurecanpenetratetheskinandcauseinfectionor
otherinjury.Topreventpersonalinjury:Relieveallpressurebeforedisconnectinguidlinesorper-
formingworkonthehydraulicsystem.Beforeapplyingpressure,makesureallconnectionsaretight
andallcomponentsareingoodcondition.Neveruseyourhandtocheckforsuspectedleaksunder
pressure.Useapieceofcardboardorwoodforthispurpose.Ifinjuredbyleakinguid,seeyour
doctorimmediately.
Failuretocomplycouldresultinminorormoderateinjury.
C0104A
Replacethehydraulicoilandltersevery5000h
Fluid:PREMIUMHYDRAULICOILHV46MULTI-GRADEANTIWEAR
Quantity:82L(21.7USgal)
NOTICE:Ifanyattachmentotherthanabucketisused,reducetheintervalofthehydraulicoilandltersreplacement.
RefertoChapter9.
1.Releaseallthepressureinthehydraulictank.Referto
page6-8.
2.Cleanthetopofthehydraulictank,andcleanthecover
ofthesuctionlter.
3.Removethecoverofthehydraulicoilsuctionlter.
4.Withapump,removethehydraulicoilfromthehy-
draulictank.
SMIL17CEX0151AA1
6-69