8-SPECIFICATIONS
Enginecoolant
OATEXTENDEDLIFECOOLANT/ANTIFREEZEisthereferencegenuineproductformachineservice.
NOTICE:NeveraddSupplementalCoolantAdditives(SCA)whenusingOATEXTENDEDLIFECOOLANT/ANTIFREEZE.
OATEXTENDEDLIFECOOLANT/ANTIFREEZEhastobeusedifrellingofthecoolingsystemisneeded.Refertothe
dedicatedprocedureandrecommendationsdescribedinChapter6.
OATEXTENDEDLIFECOOLANT/ANTIFREEZEshallbeusedforthereplacementofenginecoolantaccordingtothemain-
tenanceprogramofthemachine.Thereplacementshallalsobetackledincaseofrepairorreplacementofcompo-
nentsofthecoolingsystem.RefertothededicatedproceduredescribedinChapter6.
Theenginecoolingsystemshallalwaysberelledwithcoolantsolutionmadebymixtureofantifreezeanddistilled
(deionized)water.
NOTICE:Neverrellthecoolingsystemwithonlyantifreeze.Neverrellthecoolingsystemwithonlywater.
UsingOATEXTENDEDLIFECOOLANT/ANTIFREEZE,a50/50mixtureofantifreezeanddistilled(deionized)watergrants
properperformanceoftheenginecoolingsystemintheabovementionedoperatingtemperaturerangeofthema-
chine.
OATEXTENDEDLIFECOOLANT/ANTIFREEZEisavailableas:
50/50PREMIXEDcoolantsolutionreadyforusage.
CONCENTRATEantifreezetobemixed50/50withdistilled(deionized)water.
NOTICE:Ifoperatinginextremewinterclimate,acoolantsolutionmadeby60/40antifreeze/distilled(deionized)water
mixtureshallbeusedinordertograntproperperformanceoftheenginecoolingsystem.
NOTICE:Neverusecoolantsolutionwithmorethan60%ofantifreeze.Thisaffectsthecoolingcapacityofthemixture.
WhenthecoolantsolutionispreparedstartingfromtheCONCENTRATEproduct,theantifreezeconcentrationinthe
mixtureofantifreezeanddistilled(deionized)watercanbedeterminedwitharefractometerdesignedtomeasure
ethyleneglycolcontent.
Ifdistilled(deionized)waterisnotavailable,usewaterfordilutionwiththefollowingproperties:
PropertyMaximumlimit
TotalSolids
340ppm
TotalHardness170ppm
Chloride(Cl)
40ppm
Sulfate(SO4)
100ppm
AciditypH5.5to9.0
NOTICE:Neverusehardwater,seawaterandsoftenedseawaterthathasbeenconditionedwithsalt.Theminerals
andsaltspresentinpotablewatercancausecorrosionanddepositsresultinginshortenedenginelife.