3-CONTROLS/INSTRUMENTS
Optionalmanualregeneration
XNNFHF-001Z7
Ifthemachineisnotusedforalongtimewhentheengineisoperatinginautomaticregeneration,automaticregener-
ationmaynotstartorcompletenormally.
Insuchacase,manualregenerationmaybecompletedautomaticallybystoppingautomaticregenerationandexe-
cutingoptionalmanualregeneration.
Notethatthemachinecannotbeoperatedinoptionalmanualregenerationandtheregenerationtimetakeslonger.
Whentheswitchisheldfor3secondswhenautomaticregenerationisstopped,theorangelampblinksfor10seconds
andoperationchangesintomanualregeneration.
Whentheswitchispressedagainwhiletheorangelampisblinking,manualregenerationstarts.
Donotpresstheswitchifmanualregenerationshouldnotbestarted.
Theblinkingorangelampgoesout10secondslater.
1.Inautomaticregeneration.
•
Thegreenlampislit.
•
Thefollowingmessageisdisplayedcyclically.
AutoDPDRe-gen
2.Pressingtheswitch.
3.Automaticregenerationstops.
•
Thegreenlampgoesout.
•
Thefollowingmessageisdisplayed.
PushDPDswitchtoactivate
4.Movethemachinetoasafeplacewithnocombustibleobjects.
•
Setthefunctioncancellationlevertothelockposition(safetybarretracted).
5.Holdtheswitchfor3secondstomovetooptionalmanualregeneration.
6.Movestomanualregeneration.
•
Theorangelampblinks.
•
Thebuzzersoundsfor2seconds.
•
Thefollowingmessageisdisplayed.
PushDPDswitchtoactivate
3-46