3-CONTROLS/INSTRUMENTS
7.Presstheswitchwhilethelampisblinking(blinkinglastsfor10seconds).
NOTE:Ifyoudonotneedtoperformmanualregeneration,donotpresstheswitch.Thelampwillstopblinkingand
gooutafter10seconds.Thefollowingmessageisdisplayedagain.
PushDPDswitchtoactivate
8.Manualregenerationstarts.
•
Theorangelampislit.
•
Thebuzzersoundsfor2seconds.
•
Thefollowingmessagesaredisplayedcyclically.
ManualDPDRe-gen
Donotoperate
Regenerationtime:20to25minutes.
9.Manualregenerationiscomplete.
•
Thegaugebecomeszero.
•
Thelampgoesout.