CODE128_MIN Valid minimum digits 1 2
CODE128_MAX Valid maximum digits 98 98
0 0: With Full ASCII
conversion
1 1: Without Full ASCII
conversion
2 2: Output GS1-128 bar code
only.
6 6: Output GS1-128 bar code
only with code ID (note
2).
10 10: Output GS1-128 bar code
only after Fnc GS
conversion.
2 2: Output GS1-128 bar code
only.
4 4: Output GS1-128 bar code
with code ID attached.
8 8: Output GS1-128 bar code
after Fnc GS
conversion (note 2).
16 16: Output Code128 bar code
without Full ASCII
conversion performed.
32 32: Output GS1-128 bar code
without Full ASCII
conversion performed.
(note 2)
64 64 Output Code128 bar code
or GS1-128 bar code with
FNC2 combined.
CODE128_OUTFORMAT Output format
(note 4)
128
0
128 Output Code128 bar code
or GS1-128 bar code with
expanded FNC4 and
ASCII conversion
performed.
00: Disable CODE128_CHKD Check digit calculation
1
1
1: Enable
CODE128 Option
CODE128_CHKCH Check character output 0 0 Disable (fixed)
MSI_MIN Valid minimum digits 1 1
MSI_MAX Valid maximum digits 57 57
MSI_OUTFORMAT Output format 0 0 No (fixed)
0 0: No calculation
1 1: 1 digit, mod 10
2 2: 2 digits, mod11/mod 10
MSI_CHKD Check digit calculation
3
1
3: 2 digits, mod10/mod10
00: Disable
MSI Option
MSI_CHKCH Check character output
1
1
1: Enable