95
• Setting for Common Operations
The settings in Table 2.61 are for the common operations not related to scanning bar codes.
Table 2.61
Item Description Setting Default
[PrintWeight] Section
PrintWeight Specify the calibration value for
thickness of bars.
Specify in the range of
1 to 7.
4
[Intensity] Section
Aimer Specify the intensity of the Aimer. Specify 0 or 100. 100
Illumination Specify of the intensity of the
Illumination LED.
Specify 0 or 100. 100
[Multi-step] Section
ReadMode Specify read mode. 0; Normal read
1; Multi-step read
2; Package read
0
ReadTimes Specify the no. of times to scan in
continuous mode.
Specify in the range of
2 to 10.
2
Separator Specify the separator (= symbol) in
Package read mode.
Specify character
casted in INT-type.
0
[Scan Mode] Section
Scan Mode Specify scanning mode. 0; Outdoor
1; Indoor (window
side)
2; Indoor
3; Warehouse
1
[Decode Deliberation] Section
Decode Deliberation Set the deliberation level. 100; Extremely fast
decoding, but limited
symbologies.
200; Fast decoding with
some limited symbologies.
400; Normal
800; Slow decoding, but
adequate number of
symbologies covered.
0; Extremely slow
decoding, but many
symbologies covered
400
[Search Mode] Section
Search Mode Search mode - 1
Continue.