— 27 —
INIT
Copyright(C)2004
CASIO COMPUTER CO.,LTD. C
All rights reserved.
ROM VER xxxxxx xxxx
7 8 9
CREATE xxxx-xx-xx xx:xx
QT-6100 Version x.xx 4 5 6
APL VER. xxxxxx xxxx
1 2 3
0
OK
7. DIAGNOSTIC OPERATION
7-1. To start the diagnostic program
(1) Turn the power off.
(2) Turn the power on while pressing the INIT switch.
(3) Release the switch when the display shown below appears.
* Operation is not guaranteed if the switch is released before the display appears.
(4) Enter 99990000 and then [OK].
(5) LCD calibration test starts automatically.
Refer to "[ 12 ] LCD calibration test" for the operation details.
7-2. Notes for the DIAG
•
Make sure the printer used to print out test results is set to a baud rate of 9600 bps and is con-
nected to COM1.
•
Perform testing by connecting HHS-15 to COM2.
•
Always make sure to connect REMOTE DISP to COM3.
•
When desiring to conduct a test for an unlimited number of times, enter a value other than 0 in
accordance with the explanation for each test. Tests are performed for an unlimited number of
times when a value of 1 through 9 is entered for the commend used to specify the number of
times testing is performed in the operating procedure on each page. However, this function al-
lows a test to only be performed once or for an unlimited number times.
[Procedure and Display for Operator-Evaluated Tests]
•
In operator-evaluated tests, the results for that test are determined according to the OK and NG
keys after the following display appears.
[OK] key: Register 1 [NG] key: Register 9
•
A display that excludes the following display is shown for the LCD display of each test.
| Please Hit Key OK-> 1 NG-> 9 |
[Other]
* ESC printout and display contents for forced termination of a test by ESC are as shown below.
This display and printout are omitted in each test.
| ESC |
* That following printing of test results is omitted.