5.7.7 OPP / OPM Status LED
There are two status LEDs at the rear side of the OPP / OPM, “PWR” (Power) and “STA”
(Status), which has the following meanings.
Status
PWR
heating on
(orange, PWR)
STA (rot, controllable)
Boot process
permanently on
permanently on
Terminal ready, waiting for
login
permanently on
2x slowly blinking, 2x fast
blinking
Terminal ready, login
successful
permanently on
off
SecureLink/4eye to reader
not active
permanently on
1x slowly, 1x fast
Startup lock
permanently on
1x slowly, 2x fast
Initialization lock /
Diagnosis lock
permanently on
1x slowly, 3x fast
Fraud
permanently on
fast blinking
Not identified / other error
permanently on
permanently on
slowly blinking