6.3.2 SCR-C
temperature conditions
- operating:-20°C to 65°C (without heating)
- storage: -25°C to 75°C
humidity conditions:
- operating: 5% - 85% RH (non-condensing)
- storage: 5% - 95% RH (non-condensing)
- Emission: according EN50081-1, CLASS B
- Immunity: according EN50022
RS-232 interface: connection to OPP-C60, including power supply for the
SCR-C
Impacts and shocks to the card reader should be avoided. The max. valid
shock / impact influence should be less than the influence of the executed
tests (18 shocks, 6 per layer, 3 per direction with 11ms and 100m/s².
- Installation depth in VM: 131mm
- Total depth (incl. anti-skimming bezel): 151mm
- VM inside: 100.4mm x 70.2mm (L x W)
- Cut-out: EVA PTS conform: 74.0mm x 62.0mm (L x W)
- Material: zinc die casting
- Cut-out: 73.2mm x 61.2mm
- Dimensions: 99.7mm x 70.2mm (W x H)
- Foreign objects can be removed very simple in secure environment
- Dripping protection optional available