The gate response will be to start opening on the Trg trigger, and then to stop
as soon as the Autoclose Override time is reached. On clearing of the Trg
input, the gate will continue opening until fully open. The Autoclose feature is
nowtemporarilydisabledandthegatewillremainopenindenitely.Todisable
AutocloseoverridetheTRGinputneedstobeactivatedagain.
25.2.4. Autoclose Advanced Options
The conditions under which the gate will automatically close can be set within the
Advanced Autoclose options menu:
Autoclose Fully Open - automatically closes the gate if it has reached
the fully open position
Autoclose Partly Open - automatically closes the gate if it is stopped while
opening, but before reaching the fully opened position
Autoclose Partly Closed - automatically closes the gate if it is stopped while
closing, but before reaching the fully closed position
25.3. Menu 4 - Modes of Operation
It is possible to select the following Modes of Operation: Standard,
Condominium, and Reversing Mode. All modes are triggered by closing a
normally-opencontactbetweentheTrginputterminalandtheComterminal.
The functionality described in this section can be activated using the
onboard multichannel receiver.
25.3.1. Standard Mode
When stationary, a trigger impulse on Trg will cause the gate to either open or
close. On a moving gate, a trigger impulse on Trg will stop the gate.
The next impulse on Trg will cause the gate to reverse its direction of travel; i.e.
the action is start-stop-reverse.
25.3.2. Condominium Mode
A trigger impulse on Trg will open the gate under all conditions. If it is closing,
it will stop and reverse to open. In this Mode of Operation, the only way to close
the gate is with the Autoclose feature, which is automatically activated when
Condominium Mode is selected.
25.2.3. Reversing Mode
A trigger impulse on Trg will reverse the direction of a moving gate. If it is
closing, it will stop and immediately begin opening. If it is opening, it will stop and
immediately begin closing.