28.4. Buzzer Feedback
The V-Series Controller is equipped with an onboard buzzer which is used for various
features and functions on the Controller. One of the functions it provides is audible
diagnostic feedback as detailed.
Priority
Number
of beeps
Fault
type
Gate
continues
to operate
User
can
correct
error
Break-in
Alarm
1
1 beep periodically
for 30 seconds
Alarm N/A N/A
Ambush
Alarm
2
Periodic until
condition
is cleared by user
Alarm N/A N/A
Battery-low 3
3 beeps periodically
for 30 seconds
Power
system fault
Yes
1
Yes
Multiple
Collision
4
Periodic until
condition
is cleared by user
(500/500ms)
Collision No Yes
Holiday
Lockout
5
5 beeps after
trigger activation
User No Yes
TABLE 6
1. Gates will close fully and then shut down for two minutes
DIAGNOSTICS SECTION 28