EasyManua.ls Logo

CENTURION SYSTEMS VANTAGE - UL325 Standard Profile

Default Icon
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
page 62 www.CentSys.com
26.3. UL325 Standard Prole
Parameter Description Unit Minimum Default Maximum
Autoclose Status On/O O
Autoclose from Fully Open On/O On
Autoclose from Partly Open On/O On
Autoclose from Partly Closed On/O O
Autoclose Time min:sec 00:00 0:15 04:00
Autoclose Override Time Seconds 2 3 15
Mode of Operation STD,REV,CON
1
Standard
Motor M Opening Force Level 1 3 Max (6)
Motor M Closing Force Level 1 3 Max (6)
Motor S Opening Force Level 1 3 Max (6)
Motor S Closing Force Level 1 3 Max (6)
Maximum Collisions Collisions 1 2 2
Collision Alarm Output
Buzzer, Light,
Safe Com,
Sol, LED
Buzzer
PCM
2
Status On/O O
PCM
2
Type
Master, Slave,
Master&Slave,
Short Stop
Master
Only
PCM
2
Short Stop Distance
mm of piston
stroke
1 5 20
PCM
2
Force %(A) 33 (2A) 50 (3A) 100 (6A)
POM
3
Status On/O O
POM
3
Type
Master, Slave,
Master&Slave
Master
Only
POM
3
Force %(A) 33 (2A) 50 (3A) 100 (6A)
Leaf Delay Status On/O O
Leaf Delay
mm of piston
stroke
1 10 250
Opening Speed mm/sec 10 32 33
1. STD,REV,CON(ModesofOperation)-Standard,Reversing,Condominium
2. PCM-PositiveCloseMode
3. POM-PositiveOpenMode
TABLE 4
FACTORY DEFAULTS SCHEDULESECTION 26