26.3. UL325 Standard Prole
Parameter Description Unit Minimum Default Maximum
Autoclose Status On/O O
Autoclose from Fully Open On/O On
Autoclose from Partly Open On/O On
Autoclose from Partly Closed On/O O
Autoclose Time min:sec 00:00 0:15 04:00
Autoclose Override Time Seconds 2 3 15
Mode of Operation STD,REV,CON
1
Standard
Motor M Opening Force Level 1 3 Max (6)
Motor M Closing Force Level 1 3 Max (6)
Motor S Opening Force Level 1 3 Max (6)
Motor S Closing Force Level 1 3 Max (6)
Maximum Collisions Collisions 1 2 2
Collision Alarm Output
Buzzer, Light,
Safe Com,
Sol, LED
Buzzer
PCM
2
Status On/O O
PCM
2
Type
Master, Slave,
Master&Slave,
Short Stop
Master
Only
PCM
2
Short Stop Distance
mm of piston
stroke
1 5 20
PCM
2
Force %(A) 33 (2A) 50 (3A) 100 (6A)
POM
3
Status On/O O
POM
3
Type
Master, Slave,
Master&Slave
Master
Only
POM
3
Force %(A) 33 (2A) 50 (3A) 100 (6A)
Leaf Delay Status On/O O
Leaf Delay
mm of piston
stroke
1 10 250
Opening Speed mm/sec 10 32 33
1. STD,REV,CON(ModesofOperation)-Standard,Reversing,Condominium
2. PCM-PositiveCloseMode
3. POM-PositiveOpenMode
TABLE 4