26.3. UL325 Standard Prole (continued)
Parameter Description Unit Minimum Default Maximum
Closing Speed mm/sec 10 32 33
Ramp-upDistance
mm of piston
stroke
20 30 100
Ramp-downDistance
mm of piston
stroke
30 50 100
Crawl Distance
mm of piston
stroke
5 5 100
Push Force Limit Amps 5 15 15
Pre-OpenDelayTime min:sec 00:00 00:00 03:16
Pre-CloseDelayTime min:sec 00:00 00:00 03:16
TRGStopDistance
mm of piston
stroke
10 20 100
IRBStopDistance
mm of piston
stroke
10 20 100
PED Open Distance
% of piston
stroke
10 30 100
PED Autoclose Time min:sec 00:00 00:05 04:00
PEDPre-OpenDelayTime min:sec 00:00 00:02 04:00
PEDPre-CloseDelayTime min:sec 00:00 00:00 04:00
Gate Lock Enabled Yes/No No
Gate Lock Type Magnetic/Striker Striker
GateLockPre-ReleaseTime Seconds 0.0 0.0 24.0
GateLockReleaseTime Seconds 0.1 1.0 24.0
Gate Lock Location CLS, OPN, BTH
4
Close
Only
Gate Lock Drive Type AC, DC AC
Courtesy Light Time h:mm:ss 0:00:04 0:02:00 9:59:59
CourtesyLightProle
CUR,PFA,PFB,
PFC
5
Courtesy
TABLE 4. CONTINUED
4. CLS,OPN,BTH-ClosedPosition,OpenPosition,Both(Open&ClosedPositions)
5. CUR,PFA,PFB,PFC-Courtesy,ProleA,ProleB,ProleC
FACTORY DEFAULTS SCHEDULE SECTION 26