Edge/Edge Blanket Installation
2-15
NOTE: Do not press a red
safety STOP button. This will
cause the compressed air system
to depressurize.
Wait about 2 seconds and then press the
square red station Stop button.
Looking in from the rear of the machine,
locate the low pressure gauge of the ma
-
chine at the right center (Figure 2-28). The
air pressure gauge should be set at 60 psi
(415 kPa).
NOTE: These settings are pre-
set at the factory. Air pressures
can be changed to meet the needs
of different weights of flatwork.
The remaining pressure regulator
only needs to be checked and/or
adjusted in the case of a specific
machine performance problem.
7.
8.
WARNING
Stand clear whenever the
discharge conveyor is
moving. Failure to do so
could result in serious injury.
Standing clear of the discharge conveyor,
flip the discharge conveyor toggle switch
(Figure 2-27, A) to UP to raise the dis-
charge ribbons.
Make sure the red discharge conveyor
safety bracket engages (Figure 2-27, B).
NOTE: Be sure to release the
discharge conveyor safety bracket
before flipping the DISCHARGE
CONVEYOR UP/DOWN switch
to the DOWN position.
Disengage the safety bracket and flip the
DISCHARGE CONVEYOR UP/DOWN
switch to the DOWN position.
Leave power turned ON at the main dis
-
connect switch and the compressed air
supply ON for the next procedure.
9.
10.
11.
12.
Figure 2-26: Low air pressure regulator in center/
right of machine.
Figure 2-27: Test the DISCHARGE CONVEYOR
UP/DOWN switch.
B