Edge/Edge Blanket Preventive Maintenance
4-1
Chapter 4
PREVENTIVE MAINTENANCE
Various components and parts of the unit require scheduled attention to assure long life and trouble-
free operation.
Except for checks requiring power, always turn the electrical disconnect switch OFF before performing
preventive maintenance. Since the STOP button and safety guard tests can only be done with power on,
perform these tests with extreme caution and attention to detail.
The Preventive Maintenance (PM) Schedule outlines all of the PM tasks required at regular intervals.
All tasks are the responsibility of maintenance personnel. However, certain indicated tasks may be done
by trained operators.
All PM intervals are based on 8 hours/day operation. Increase the frequency for 2 or 3 shift
operations.
FREQUENCY OF TASKS BASED ON 40 HOURS PER WEEK OPERATION
Preventive Maintenance Tasks Operator Maintenance Unit Condition
4.1 DAILY (8 hours)
Watch and Listen for Anything Abnormal X Running
General Cleanliness
X Off/Disconnect Power
Check Safety Equipment
X X Running
4.2 WEEKLY (50 hours)
Clean Photosensors and Reflectors X Off/Disconnect Power
Check and Clean Inverters
X Off/Disconnect Power
Check For String Accumulation
X Off/Disconnect Power
Check Rodless Air Cylinder Bearings
X Off/Disconnect Power
Check Clutch-Brake Roller Alignment
X Off/Disconnect Power
Lubricate Upper Spreader Rail
X Off/Disconnect Power
Check Spreader Clamp Linear Assembly Bearings
X Off/Disconnect Power
Inspect Air Filter/Regulator/Drain
X Off/Disconnect Power
Check Air Pressure Settings
X Off/Power Connected
Check Discharge Ribbon Condition
X Running
4.3 MONTHLY (200 hours)
Check Upper and Lower Spreader Belts Condition and
Tension
X Off/Disconnect Power
Inspect Drive Belt Condition
X Off/Disconnect Power
Check Setscrews
Clean and Lubricate Drive Chain
X Off/Disconnect Power
4.4 SEMI-ANNUAL (1000 hours)
Clean Air Filter/Regulator/Drain X Off/Disconnect Power
Check and Grease Bearings
X Off/Disconnect Power
Replace Rodless Air Cylinder Bearings
X Off/Disconnect Power
4.5 ANNUAL (2000 hours)
Check All Electrical Connections X Off/Disconnect Power
Check Insulation Resistance to Earth Ground
X Off/Disconnect Power