EasyManua.ls Logo

Chroma 19572 - Step Hold Time ≠ Key, Fail Cont. = off; Step Hold Time = Key, Fail Cont. = on

Chroma 19572
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ground Bond Tester 19572 Users Manual
9-2
9.5 STEP HOLD TIME
KEY, FAIL CONT. = ON
1. After all steps are tested, LCD shows PASS. Please refer item 1 in section 9.3.
2. After all steps are tested, LCD shows FAIL. Please refer item 2 in section 9.3.
3. If FAIL occurred in a certain of STEP and under test. Please refer item 1 in section 9.2.
9.6 STEP HOLD TIME = KEY, FAIL CONT. = ON
1. After all steps are tested, whatever LCD shows PASS or FAIL, INTERLOCK OPEN at this
time. If START key was pressed, all STEP states are initialized and stays on STEP1
screen then the left down side of LCD shows CAN NOT TEST. By using RS232 or GPIB
interface, give [:SOURce]: SAFEty:RESult[:LAST][:JUDGment]? command to query
the judgment result, return code is 114.
2. When WAIT KEY, please refer item 2 in section 9.4.

Table of Contents

Related product manuals