Remote Operation
8-25
[SOURce :] SYNThesis : AMPLitude
Description : This command sets the amplitude of each harmonic order. The
maximum number of order is 40.
Query Syntax : [SOURce :] SYNThesis : AMPLitude?
Parameters : <NR2>, …, <NR2>
valid range:
Order VALUE PERCENT
2 ~ 10
11 ~ 20
21 ~ 30
31 ~ 40
0 ~ 150.0
0 ~ 120.0
0 ~ 80.0
0 ~ 45.0
0 ~ 100.00
0 ~ 50.00
0 ~ 30.00
0 ~ 15.00
Return Parameters : <NR2>, …,<NR2>
[SOURce :] SYNThesis : PHASe
Description : This command sets the phase angle of each harmonic order.
Query Syntax : [SOURce :] SYNThesis : PHASe?
Parameters : <NR2>, …, <NR2> valid range: 0.0 ~ 359.9
Return Parameters : <NR2>, …, <NR2>
[SOURce :] SYNThesis : FUNDamental
Description : This command sets the fundamental AC voltage of
SYNTHESIS mode.
Query Syntax : [SOURce :] SYNThesis : FUNDamental?
Parameters : <NR2>, valid range: 0.0 ~ 150.0 (in low range), 0.0 ~ 300.0 (in
high range)
Return Parameters : <NR2>
[SOURce :] SYNThesis : DC
Description : This command sets the DC voltage which adds to voltage
waveform of SYNTHESIS mode.
Query Syntax : [SOURce :] SYNThesis : DC?
Parameters : <NR2>, valid range: -212.1 ~ 212.1 (in low range), -424.2 ~
424.2 (in high range)
Return Parameters : <NR2>
[SOURce :] SYNThesis : FREQuency
Description : This command sets fundamental frequency of SYSTHESIS
mode.
Query Syntax : [SOURce :] SYNThesis : FREQuency?
Parameters : 50Hz | 60Hz
Return Parameters : 50Hz | 60Hz
[SOURce :] SYNThesis : SPHase
Description : This command sets the start phase angle of SYNTHESIS
mode.
Query Syntax : [SOURce :] SYNThesis : SPHase?
Parameters : <NR2>, valid range: 0.0 ~ 359.9
Return Parameters : <NR2>
OUTPut : MODE
Description : This command sets the operation mode. The user should quit
the output before setting OUTPut : MODE SYNTH.