Remote Operation
8-15
[SOURce :] VOLTage : LIMit : DC : PLUS
Description : This command sets the setting of Vdc LIMIT(+) which will
restrict the value of Vdc.
Query Syntax : [SOURce :] VOLTage : LIMit : DC : PLUS?
Parameters : <NR2>, valid range: 0.0 ~ 424.2 (unit: V)
Return Parameters : <NR2>
[SOURce :] VOLTage : LIMit : DC : MINus
Description : This command sets the setting of Vdc LIMIT(-) which will
restrict the value of Vdc.
Query Syntax : [SOURce :] VOLTage : LIMit : DC : MINus?
Parameters : <NR2>, valid range: 0.0 ~- 424.2 (unit: V)
Return Parameters : <NR2>
[SOURce :] VOLTage : RANGe
Description : This command sets output voltage range with three options of
LOW(150 V), HIGH(300 V), or AUTO.
Query Syntax : [SOURce :] VOLTage : RANGe?
Parameters : LOW | HIGH | AUTO
Return Parameters : LOW | HIGH | AUTO
8.6.2.4 CONFIGURE Sub-system
[SOURce :]
CONFigure
: INHibit
: EXTernal
: COUPling
[SOURce :] CONFigure : INHibit?
Description : This command sets REMOTE INHIBIT state. There are three
states for the feature of remote inhibit : OFF, LIVE, and TRIG.
Query Syntax : [SOURce :] CONFigure : INHibit?
Parameters : OFF | LIVE | TRIG
Return Parameters : OFF | LIVE | TRIG
[SOURce :] CONFigure : EXTernal
Description : This command enables or disables the external controlled
analog signal input from external devices.
Query Syntax : [SOURce :] CONFigure : EXTernal?
Parameters : OFF | ON
Return Parameters : OFF | ON
[SOURce :] CONFigure : COUPling?
Description : This command sets the coupling mode to present AC source
output from external V reference: AC_AMPLIFIER and
DC_LEVEL_CTL.
Query Syntax : [SOURce :] CONFigure : COUPling?
Parameters : AC | DC
Return Parameters : AC | DC