EasyManua.ls Logo

Chroma 61503 - Page 97

Default Icon
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Operation
8-15
[SOURce :] VOLTage : LIMit : DC : PLUS
Description : This command sets the setting of Vdc LIMIT(+) which will
restrict the value of Vdc.
Query Syntax : [SOURce :] VOLTage : LIMit : DC : PLUS?
Parameters : <NR2>, valid range: 0.0 ~ 424.2 (unit: V)
Return Parameters : <NR2>
[SOURce :] VOLTage : LIMit : DC : MINus
Description : This command sets the setting of Vdc LIMIT(-) which will
restrict the value of Vdc.
Query Syntax : [SOURce :] VOLTage : LIMit : DC : MINus?
Parameters : <NR2>, valid range: 0.0 ~- 424.2 (unit: V)
Return Parameters : <NR2>
[SOURce :] VOLTage : RANGe
Description : This command sets output voltage range with three options of
LOW(150 V), HIGH(300 V), or AUTO.
Query Syntax : [SOURce :] VOLTage : RANGe?
Parameters : LOW | HIGH | AUTO
Return Parameters : LOW | HIGH | AUTO
8.6.2.4 CONFIGURE Sub-system
[SOURce :]
CONFigure
: INHibit
: EXTernal
: COUPling
[SOURce :] CONFigure : INHibit?
Description : This command sets REMOTE INHIBIT state. There are three
states for the feature of remote inhibit : OFF, LIVE, and TRIG.
Query Syntax : [SOURce :] CONFigure : INHibit?
Parameters : OFF | LIVE | TRIG
Return Parameters : OFF | LIVE | TRIG
[SOURce :] CONFigure : EXTernal
Description : This command enables or disables the external controlled
analog signal input from external devices.
Query Syntax : [SOURce :] CONFigure : EXTernal?
Parameters : OFF | ON
Return Parameters : OFF | ON
[SOURce :] CONFigure : COUPling?
Description : This command sets the coupling mode to present AC source
output from external V reference: AC_AMPLIFIER and
DC_LEVEL_CTL.
Query Syntax : [SOURce :] CONFigure : COUPling?
Parameters : AC | DC
Return Parameters : AC | DC

Table of Contents

Related product manuals