Remote Operation
8-13
OUTPut : SLEW : VOLTage : DC
Description : This command sets the slew rate of the DC composition
voltage.
Query Syntax : OUTPut : SLEW : VOLTage : DC?
Parameters : <NR2>, valid range: 0.000V/ms ~ 1000.000V/ms
Return Parameters : <NR2>
OUTPut : MODE
Description : This command sets the operation mode. “FIXED” MODE is
normal used.
Query Syntax : OUTPut : MODE?
Parameters : FIXED | LIST | PULSE | STEP | INTERHAR
Return Parameters : FIXED | LIST | PULSE | STEP | INTERHAR
OUTPut : PROTection : CLEar
Description : This command clears the latch that disables the output when an
overcurrent (OC), overtemperature (OT), overpower (OP) or
remote inhibit (RI) is detected. All conditions, which have
generated the fault, must be removed before the latch is
cleared.
Query Syntax : None
Parameters : None
Return Parameters : None