40
Enter Setup
1560 Series Barcode Scanner User Guide
1.10 ADDON SECURITY FOR UPC/EAN BARCODES
You may like to enforce read redundancy (0~30 times) on UPC/EAN barcodes with
addons only.
Note: UPC/EAN Addon 2 and Addon 5 must be enabled individually for this setting to
take effect.
1) Read the label above to specify the read redundancy when missing add-ons while
scanning UPC/EAN barcodes. (It is set to 0 by default.)
2) Read the “
Decimal Value” label on page 205. For example, read “1” and “2” for the
scanner to re-read the barcode for 12 times.
3) Read the “Validate” label on the same page to complete this setting.
Addon Security Level (*0 ~ 30)