74
Enter Setup
1560 Series Barcode Scanner User Guide
2.5.7 INTER-CHARACTER DELAY
By default, the inter-character delay is zero. Specify a value, ranging from 0 to 254 in
units of millisecond, to match the computer response time. Such delay time is inserted
between every character being transmitted. The longer the delay time is, the slower the
transmission speed will be.
1) Read the label above to specify the inter-character delay.
2) Read the “
Decimal Value” label on page 205 for the desired inter-character delay
(millisecond).
3) Read the “Validate” label on the same page to complete this setting.
2.5.8 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254
in units of millisecond, to match the computer response time of the keyboard interface.
Such delay time is inserted between every function code (0x01 ~ 0x1F) being
transmitted. The longer the delay time is, the slower the transmission speed will be.
Data Ready
I
nvert Data Ready
I
nter-Character Delay … (*0 ~ 25
Inter-Function Delay … (*0 ~ 25
S
canner Ready

Table of Contents