Appendix A Technical Specifications
A-2
Catalyst 2970 Switch Hardware Installation Guide
OL-6422-01
Table A-2 Specifications for the Catalyst 2970G-24TS Switch
Environmental Ranges
Operating temperature 32 to 113°F (0 to 45°C)
Storage temperature 13 to 158°F (25 to 70°C)
Relative humidity 10 to 85% (noncondensing)
Operating altitude Up to 10,000 ft (3049 m)
Storage altitude Up to 15,000 ft (4573 m)
Power Requirements
AC input voltage 100 to 240 VAC (autoranging)
2.3 A/1.5 A, 50 to 60 Hz
DC input voltages for
RPS 675
+ 12 V @17 A
Power consumption 190 W, 650 BTUs per hour
Power rating 0.190 kVA
Physical Dimensions
Weight 12.5 lb (5.68 kg)
Dimensions (H x D x W) 2.59 x 11.60 x 17.5 in. (6.59 x 29.46 x 44.45 cm)