Chapter 6 Service and Maintenance
342
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
FEC USB Flash
(D9854-I only)
Set
FEC USB Flash not
found
Cause: FEC USB
FLASH not
installed. This
may occur in
Production if the
USB module is not
inserted before the
first power on the
board.
Remedy: Ensure
that the FEC USB
connector and
FLASH module
are installed.
FEC USB
FLASH mount
failed.
Major
92300
FEC USB Flash
(D9854-I only)
Clear
FEC USB Flash
OK
Major
92300
FEC FPGA
Status
(D9854-I only)
Set
Failed to find or
load FEC FPGA
binary
Cause: Cannot
find the FEC
FPGA file in the
USB FLASH, or it
failed to open,
read, or load the
file to the FEC
FPGA.
Remedy: Ensure
that the USB
FLASH is
installed,
formatted, and the
image is loaded.
Also, ensure that
the FEC FPGA is
installed and the
CPLD is properly
programmed.
The FEC FPGA
image is not
found in the
USB FLASH, or
the file cannot
be loaded to
the FEC FPGA
for any reason.
This will occur
in production
until the USB
FLASH is
installed,
formatted, and
the image is
loaded.
Major
92400