Status Menu
63
Menu Item
Description
Parameters
SR Status
This displays the status of an
alternate authorized
program/service from the same
transport stream when the receiver
is not authorized to view the
primary program. This is an uplink
initiated function that maps the
alternate service to the original
(primary) service PIDs, replacing
the original service with the
alternate service at the digital
transport output. No local
intervention is required by the
receiver operator for provision of
this service replacement feature.
Not Started - Indicates that an event has
not started.
Primary - Indicates that a service
replacement event is active, but the
primary program is being displayed.
Alternate - Indicates that a service
replacement event is active, and that the
receiver has tuned to and is displaying
the alternate program/event as it is not
authorized to view the scheduled event.
SR Event Type
Indicates the type of service
replacement event.
None - Indicates that no service
replacement event is scheduled.
Scheduled - Indicates that all receivers
will tune to the alternate program at the
scheduled time. This status applies to
PE1 (PowerVu) only.
CA - Indicates that only receivers
unauthorized to view the scheduled
program will tune to the alternate
program according to the selected
authorization tier bits. This status
applies to PE1 (PowerVu) only.
Cue Trigger - Indicates that only
receivers authorized by the Cue Trigger
mask will tune to the scheduled
program/event. Cue triggers can only
be initiated/controlled on PE1 (i.e.,
PowerVu).
SR Event Start
Displays the start time of the
service replacement event when
one is scheduled; otherwise, the
default start time is displayed. The
default start time is 2007/09/01
00:00:00.
–
SR Event End
Displays the end time of the service
replacement event when one is
scheduled; otherwise, the default
end time is displayed. The default
end time is 2007/09/01 00:00:00.
–