Design SpecificationDescription
-40° to 140°F (-40° to 60°C) in a sealed NEMA cabinet with no airflow-40° to
158°F (-40° to 70°C) in a vented cabinet with 40 LFM of air-40° to 167°F (-40°
to 75°C) in a forced air enclosure with 200 LFM of air(type tested at +85°C for
16 hours)NOTE: This product has been safety certified up to 60°C maximum
ambient.-500 to 5,000 feet. Derate max operating temperature 1.5°C per 1000
feet.
Operating Temperature and Altitude on the Base
IR1101 with WP7600 Series Modems.
Note: See EM74XX Modem Specifications, on
page 79 for the EM74XX Series Modems.
10 – 95%Humidity
Nominal voltage: 12V to 48V DCMin/Max voltage: 9.6V to 60V DC inputInput Voltage
12V - 0.72A24V - 0.36A59.8V - 0.17ATypical Current
Without LTE Pluggable: Typical 7.7W, Maximum 10WWith LTE Pluggable:
Typical 10W, Maximum 13W
Typical/Maximum Power Consumption
IRM-1100 Expansion Unit
The following table lists the Expansion Unit specifications:
Table 24: Cisco IRM-1100 Specifications
Design SpecificationDescription
13.3(h) x 12.5(d) x 5.8(w) cm (5.22" x 4.92" x 2.27")Dimensions
1.6 lbs.Weight
IP 30Ingress Protection Rating
Non-condensing Relative Humidity: 5% to 95%Humidity
UL 60950-1, 2nd edition; CAN/CSA C22.2 No. 60950-1, 2nd edition, EN
60950-1, 2nd edition; CB to IEC 60950-1, 2nd edition with all group differences
and national deviations.
Standard Safety Certifications
-40° to 140°F (-40° to 60°C) in a sealed NEMA cabinet with no airflow-40° to
158°F (-40° to 70°C) in a vented cabinet with 40 LFM of air-40° to 167°F (-40°
to 75°C) in a forced air enclosure with 200 LFM of air(type tested at +85°C for
16 hours)NOTE: This product has been safety certified up to 60°C maximum
ambient.-500 to 5,000 feet. Derate max operating temperature 1.5°C per 1000
feet.
Operating Temperature and Altitude on the
Expansion IRM-1100 with WP7600 Series
Modems.
Note: See EM74XX Modem Specifications, on
page 79 for the EM74XX Series Modems.
10 – 95%Humidity
IR1101 Industrial Integrated Services Router Hardware Installation Guide
78
Technical Specifications
IRM-1100 Expansion Unit