Support
model
- 359 -
fn=12: Function 12 Sending the Set Communication Conditions
GS ( E pL pH fn a
[Code] <1D>H<28>H<45>H<pL><pH><fn><a>
[Range] (pL+pH×256)=2 (pL=2, pH=0)
fn=12
1≤a≤4 (Does not send in other than specified range)
[Outline] [The specification which is common to the model]
• Sends communication conditions of serial interface specified by “a”.
Kind of communication conditions (a)
• Set value
a=1: At specification of baud rate
◎
◎---support by CT-S280/CT-S281/CT-S2000/CT-S4000/CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/
CT-S310II/CT-S251
●---support by CT-S280/CT-S2000/CT-S4000/CT-P29x series/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D151/ CT-E651
(CT-P29x series does not support 115200bps)
a=2: At specification of parity
a=3: At specification of flow control
a=4: At specification of data length